MegAtec 360 — wall and ceiling expansion joint cover

Aluminium wall expansion joint cover for wall-to-wall and corner/ceiling-to-wall applications, rated to ASTM E-1399 for thermal, wind and seismic movement — one of the few MegAtec variants rated for seismic use.

Get a joint scheduleSend your BOQ for a quote

Specifications

Movement capacityGap widths 25, 50, 75, 100, 150, 200 mm. Wall-to-wall (A07): ±12 to ±100 mm. Corner/ceiling-to-wall (A09): ±6 to ±50 mm (gap-dependent — see TDS)
StandardASTM E-1399 · Class I (Thermal), Class II (Wind), Class III (Seismic)
ApplicationWall to wall, or corner & ceiling to wall — not a floor system
CPWD DSRSupplied against item 5.45 (wall joint). What the item asks for, and what to add to the BOQ
SurfaceNo visible fixings
Material6063 T5 & T6 aluminium, 20/25 micron clear satin anodised finish. Frame height 16 mm
Fire & waterproofingFire barrier available on request; rating confirmed per job; moisture-barrier waterproofing
MegAtec 360 A09 corner and ceiling to wall — cross-section detail (illustration, not to scale)

Installation

Wall-to-wall (A07) and corner/ceiling-to-wall (A09) use different fixing details and blockout dimensions — the A09 variant adds a sightline and blockout allowance the A07 doesn't need. Because the right detail depends on which junction you're joining, request CAD detail for your specific substrate rather than assuming a generic floor-joint fixing pattern; this is not a floor system.

Applications

Airport TerminalsEducationalExhibition CentresDepartment StoresDistribution & Retail WarehousesFactoriesHospitalsMuseumsOffices & HotelsParkingRail, Metros & Elevated Rail StationsShopping CentresSports Stadiums

Movement

The MegAtec 360-A07, animated through each direction it is rated to move. These are Vexcolt-group animations, not site footage; the movement each gap takes is in the data sheet.

Movement animation · MegAtec 360-A07 · illustrative
Where it's installed

The MegAtec 360 on our projects

Twelve of our written-up projects use the 360.

Specification

A clause written to the MegAtec 360 data sheet

Worked for a 100 mm wall joint. Change the gap and the movement for each location on the joint schedule and leave the rest. It names what the joint must do rather than who makes it, so an alternative has to match the performance, not just the description.

Supply and install a wall and ceiling expansion joint cover system, wall to wall and corner or ceiling to wall, to the locations scheduled, for a nominal structural gap of 100 mm, accommodating a movement of not less than ±50 mm. The system shall be cyclically tested to ASTM E-1399, Classes I, II and III, and the test evidence submitted. No fixings shall be visible on the finished face. A continuous moisture barrier membrane shall be installed within the joint and lapped to the structural waterproofing on both sides; the lap is within this subcontract. Where the joint crosses a fire compartment line, a fire barrier rated to the compartment is included (available on request; rating confirmed per job). Manufacture shall be against a site survey of the built gap taken after the structure is complete. The technical data sheet, the cross-section for each location and the installation method statement shall be submitted for approval before manufacture.

Each requirement is explained in how to specify an expansion joint. Writing to a CPWD tender? See the DSR items. See also expansion joints in buildings and the types of expansion joint.